York Process Systems

Address 1 CV Avenue Waynesboro PA 17268 United States Phone: +1 717-762-2121 Website: York Process Systems Website Ads In CTSS: York Process System Advertisement in CTSS

Company Profile

Photo of York Process Systems

York Process Systems, a business unit of Johnson Controls Incorporated, is a global leader in process refrigeration and gas compression systems, offering extensive engineering, factory packaging, control system, and field service capabilities. With manufacturing facilities in the U.S., Brazil, China, and several European locations, as well as a sophisticated, new $6.7 million U.S. screw compressor testing laboratory, the company provides proven solutions to the oil and gas, and petrochemical industries across the globe.

Frick® brand screw compressors and York® brand centrifugal compressors are utilized in customized systems, while some process cooling requirements can be handled by modified standard chiller products. From the beginning, our engineers help to configure the optimum system for your specific needs.

The Frick RXF, RWF II and HPS Series oil-flooded rotary screw compressor units cover a broad range from 120-14,000 m3/hr (70 – 8250 ft3/m), with pressures as high as 50 Bar (725 psig). The York Turbomaster horizontal split gas multistage centrifugal compressor is available in one to eight stages, with flows up to 40,000 m3/hr (24 000 ft3/m) and discharge pressures as high as 41 Bar (600 psig).

Applications include both open systems and closed cycle refrigeration.

Typical installations include natural gas gathering and processing, fuel gas compression, process compression, and process refrigeration using propane, propylene, ammonia, and the latest alternative refrigerants including R-134A, R-507, R-410A, and others. The process refrigeration applications include natural gas liquids recovery and dew point control, NGL and LNG boil-off, polysilicon production, industrial gases, chlorine liquefaction, ammonia storage, pharmaceutical manufacturing, downstream petrochemical, and environmental test chambers.

Common drivers are electric motors, steam turbines, and gas turbines. Control of the compression and refrigeration systems is accomplished either with proprietary microprocessor designs, or customized PLC systems using Allen-Bradley or Siemens platforms.

Regardless of your location, following successful installation and commissioning, locally-based teams of Johnson Controls/York factory-trained technicians will provide preventive maintenance, troubleshooting, repair, and retrofit services.

Notes

Centrifugal Compressors

ManufacturerModelAxial Flow Multi- StageAxial Flow Fixed Stator VanesAxial Flow Variable Stator VanesRadial Flow Single StageRadial Flow Multi- StageRadial Flow Horiz. SplitRadial Flow Vertical SplitRadial Flow Intergral GearRadial Flow Intergral ElectricThermal Single StageThermal Multi- StageOF = Oil Free OI = Oil InjectedInlet Flow Range acfm; Min.Inlet Flow Range acfm; Max.Inlet Flow Range m3/min; Min.Inlet Flow Range m3/min; Max.MAWP psigMAWP barCompression RatioMax. Input Power; hpMax. Input Power; kWSpeed Range RPM; Min.Speed Range RPM; Max
York ProcessM_25B    XX     OF4001800115160041.025001865 24,980
York ProcessM_25A    XX     OF10002650287560041.025001865 20,610
York ProcessM_26B    XX     OF210039006011060041.050003730 16,900
York ProcessM_26A    XX     OF330056009415960041.050003730 13,930
York ProcessM_38B    XX     OF4600840013023860041.010,8008055 11,450
York ProcessM_38A    XX     OF700012,20019834660041.010,80080559410
York ProcessM_55B    XX     OF10,00018,50028352445031.017,30012,9007720
York ProcessM_55A    XX     OF14,20023,00040265145031.017,30012,9006540

Rotary Compressors

ManufacturerModelSingle StageMulti StageStraight LobeHelical LobeSingle ScrewSliding VaneLiquid-RingTrochoidalScrollOF = Oil Free OI = Oil InjectedInlet Flow Range - acfm, Min.Inlet Flow Range - acfm, MaxInlet Flow Range - m3/min, Min.Inlet Flow Range - m3/min, MaxMAWP psigMAWP barMax. Allow Rod Load, lbMax. Allow Rod Load, newtonsCompress RatioMax. Input Power hpMax. Input Power kWSpeed Range RPM, minSpeed Range RPM, max
York/Frick (JCI)RXF-15XOI89.002.5033423.05772
York/Frick (JCI)RXF-19XOI1113.1033423.04661
York/Frick (JCI)RXF-24XOI1444.1033423.03550
York/Frick (JCI)RXF-30XOI1805.1033423.05772
York/Frick (JCI)RXF-39XOI2236.3033423.04661
York/Frick (JCI)RXF-50XOI2928.3033423.03550
York/Frick (JCI)RXF-58XOI3419.7033423.06297
York/Frick (JCI)RXF-68XOI40311.433423.05332
York/Frick (JCI)RXF-85XOI49914.133423.04306
York/Frick (JCI)RXF-101XOI59616.933423.03600
York/Frick (JCI)RWFII-100XOI5926.8060041.04500
York/Frick (JCI)RWFII-134XOI79022.460041.04500
York/Frick (JCI)RWFII-177XOI104229.560041.04500
York/Frick (JCI)RWFII-222XOI131137.160041.04500
York/Frick (JCI)RWFII-270XOI158945.060041.04500
York/Frick (JCI)RWFII-316XOI186552.860041.03600
York/Frick (JCI)RWFII-399XOI234966.560041.03600
York/Frick (JCI)RWFII-480XOI282480.060041.03600
York/Frick (JCI)RWFII-496XOI292082.760041.03600
York/Frick (JCI)RWFII-546XOI321691.160041.03600
York/Frick (JCI)RWFII-676XOI398211360041.03600
York/Frick (JCI)RWFII-852XOI501214270048.03600
York/Frick (JCI)RWHII-856XOI506814460041.03600
York/Frick (JCI)RWFII-1080XOI639418160041.03600
York/Frick (JCI)RWHII-1179XOI694019760041.03600
York/Frick (JCI)RWHII-1395XOI821223360041.03600
York/Frick (JCI)HPS 1510XOI3469.80130090.06000
York/Frick (JCI)HPS 2709XOI97427.6130090.03600
York/Frick (JCI)HPS 2712XOI129836.8130090.03600