Prime Mover Specifications

Specs – Variable Speed Drives

From the Illustrated Dictionary of Essential Process Machinery Terms
Used to control flow in a system; recommended for circulating systems and any other….

ManufacturerModelOutput Range
(kW) (min)
Output Range
(kW) (max)
Max. Motor
Volt. (kW)
Max. Output
Freq (Hz)
Rectifier TypeDrive TypeStep Num. of Inverter OutputSemiconductors (Rectifier)Semiconductors (Inverter)Motor TypeCooling
GE Power ConversionMV730338003.330012 PulseVSI3 LevelDiodeIGBTIM or SMW
GE Power ConversionMV7303 AFE38003.3300AFEVSI3 LevelIGBTIGBTIM or SMW
GE Power ConversionMV730669003.330012 PulseVSI3 LevelDiodeIGBTIM or SMW
GE Power ConversionMV7306 AFE69003.3300AFEVSI3 LevelIGBTIGBTIM or SMW
GE Power ConversionMV731010,8003.330012 PulseVSI3 LevelDiodeIGBTIM or SMW
GE Power ConversionMV7310 AFE88003.3300AFEVSI3 LevelIGBTIGBTIM or SMW
GE Power ConversionMV731213,3003.3030024 PulseVSI3 LevelDiodeIGBTIM or SMA
GE Power ConversionMV7312 AFE13,3003.30300AFEVSI3 LevelIGBTIGBTIM or SMA
GE Power ConversionMV731515,0003.3030024 PulseVSI3 LevelDiodeIGBTIM or SMA
GE Power ConversionMV7315 AFE13,3003.30300AFEVSI3 LevelIGBTIGBTIM or SMA
GE Power ConversionMV760770005.230024 PulseVSI3 LevelDiodeIGBTIM or SMW
GE Power ConversionMV761590005.230024 PulseVSI3 LevelDiodeIGBTIM or SMW
GE Power ConversionMV760910,0006.630024 PulseVSI3 LevelDiodeIGBTIM or SMW
GE Power ConversionMV7609 AFE80006.6300AFEVSI3 LevelIGBTIGBTIM or SMW
GE Power ConversionMV761615,4006.630024 PulseVSI3 LevelDiodeIGBTIM or SMW
GE Power ConversionMV761818,0006.630024 PulseVSI3 LevelDiodeIGBTIM or SMW
GE Power ConversionMV7618 AFE14,3006.6300AFEVSI3 LevelIGBTIGBTIM or SMW
GE Power ConversionMV782121,0008.230036 PulseVSI3 LevelDiodeIGBTIM or SMW
GE Power ConversionMV791313,00010.030036 PulseVSI3 LevelDiodeIGBTIM or SMW
GE Power ConversionMV792727,00010.030036 PulseVSI3 LevelDiodeIGBTIM or SMW
GE Power ConversionMV7927 AFE27,00010.0300AFEVSI3 LevelIGBTIGBTIM or SMW
GE Power Conversion2xMV792754,00010.03002 x 36 PulseVSI5 LevelDiodeIGBTIM or SMW
GE Power Conversion3xMV792781,00010.03003 x 36 PulseVSI7 LevelDiodeIGBTIM or SMW
GE Power ConversionSD7104FA6640001.51006 PulseLCI6 PulseThyristorThyristorSMA
GE Power ConversionSD7308FAC680002.910012 PulseLCI6 PulseThyristorThyristorSMA
GE Power ConversionSD7615FAC615,0005.810012 PulseLCI6 PulseThyristorThyristorSMA
GE Power ConversionSD7625FAC625,0005.910012 PulseLCI6 PulseThyristorThyristorSMA
GE Power ConversionSD7425WFCC25,0004.410012 PulseLCI12 PulseThyristorThyristorSMW
GE Power ConversionSD7640WFCC40,0008.410012 PulseLCI12 PulseThyristorThyristorSMW
GE Power ConversionSD7860WFCC60,00011.010012 PulseLCI12 PulseThyristorThyristorSMW
GE Power ConversionSD71280WFCC80,00011.010012 PulseLCI12 PulseThyristorThyristorSMW
GE Power ConversionMV4401-032504.190AFEVSI5 LevelIGBTIGBTIM or SMA
GE Power ConversionMV4401-043004.190AFEVSI5 LevelIGBTIGBTIM or SMA
GE Power ConversionMV4401-053754.190AFEVSI5 LevelIGBTIGBTIM or SMA
GE Power ConversionMV4401-064504.190AFEVSI5 LevelIGBTIGBTIM or SMA
GE Power ConversionMV4401-075004.190AFEVSI5 LevelIGBTIGBTIM or SMA
GE Power ConversionMV4401-086004.190AFEVSI5 LevelIGBTIGBTIM or SMA
GE Power ConversionMV4401-096504.190AFEVSI5 LevelIGBTIGBTIM or SMA
GE Power ConversionMV4401-107504.190AFEVSI5 LevelIGBTIGBTIM or SMA
GE Power ConversionMV4401-1210004.190AFEVSI5 LevelIGBTIGBTIM or SMA
GE Power ConversionMV4402-1511004.190AFEVSI5 LevelIGBTIGBTIM or SMA
GE Power ConversionMV4402-1713004.190AFEVSI5 LevelIGBTIGBTIM or SMA
GE Power ConversionMV4402-2015004.190AFEVSI5 LevelIGBTIGBTIM or SMA
GE Power ConversionMV4402-2520004.190AFEVSI5 LevelIGBTIGBTIM or SMA
GE Power ConversionMV4403-3022504.190AFEVSI5 LevelIGBTIGBTIM or SMA
GE Power ConversionMV4403-3525004.190AFEVSI5 LevelIGBTIGBTIM or SMA
GE Power ConversionMV4403-4030004.190AFEVSI5 LevelIGBTIGBTIM or SMA
GE Power ConversionMV4404-4532504.190AFEVSI5 LevelIGBTIGBTIM or SMA
GE Power ConversionMV4404-5037504.190AFEVSI5 LevelIGBTIGBTIM or SMA
GE Power ConversionMV6601-033856.67536 PulseVSI5 LevelDiodeIGBTIM or SMA
GE Power ConversionMV6601-033856.675AFEVSI5 LevelIGBTIGBTIM or SMA
GE Power ConversionMV6601-055506.67536 PulseVSI5 LevelDiodeIGBTIM or SMA
GE Power ConversionMV6601-055506.675AFEVSI5 LevelIGBTIGBTIM or SMA
GE Power ConversionMV6601-088256.67536 PulseVSI5 LevelDiodeIGBTIM or SMA
GE Power ConversionMV6601-088256.675AFEVSI5 LevelIGBTIGBTIM or SMA
GE Power ConversionMV6601-1011006.67536 PulseVSI5 LevelDiodeIGBTIM or SMA
GE Power ConversionMV6601-1011006.675AFEVSI5 LevelIGBTIGBTIM or SMA
GE Power ConversionMV6603-1313756.67536 PulseVSI5 LevelDiodeIGBTIM or SMA
GE Power ConversionMV6603-1616506.675AFEVSI5 LevelIGBTIGBTIM or SMA
GE Power ConversionMV6603-1616506.67536 PulseVSI5 LevelDiodeIGBTIM or SMA
GE Power ConversionMV6603-1919256.675AFEVSI5 LevelIGBTIGBTIM or SMA
GE Power ConversionMV6603-2222006.67536 PulseVSI5 LevelDiodeIGBTIM or SMA
GE Power ConversionMV6603-2222006.675AFEVSI5 LevelIGBTIGBTIM or SMA
GE Power ConversionMV6603-2424756.67536 PulseVSI5 LevelDiodeIGBTIM or SMA
GE Power ConversionMV6603-2424756.675AFEVSI5 LevelIGBTIGBTIM or SMA
GE Power ConversionMV6603-2727506.67536 PulseVSI5 LevelDiodeIGBTIM or SMA
GE Power ConversionMV6603-2727506.675AFEVSI5 LevelIGBTIGBTIM or SMA
GE Power ConversionMV6606-3030256.67536 PulseVSI5 LevelDiodeIGBTIM or SMA
GE Power ConversionMV6606-3030256.675AFEVSI5 LevelIGBTIGBTIM or SMA
GE Power ConversionMV6606-3333006.67536 PulseVSI5 LevelDiodeIGBTIM or SMA
GE Power ConversionMV6606-3333006.675AFEVSI5 LevelIGBTIGBTIM or SMA
GE Power ConversionMV6606-3838506.67536 PulseVSI5 LevelDiodeIGBTIM or SMA
GE Power ConversionMV6606-3838506.675AFEVSI5 LevelIGBTIGBTIM or SMA
GE Power ConversionMV6606-4444006.67536 PulseVSI5 LevelDiodeIGBTIM or SMA
GE Power ConversionMV6606-4444006.675AFEVSI5 LevelIGBTIGBTIM or SMA
GE Power ConversionMV6606-4949506.67536 PulseVSI5 LevelDiodeIGBTIM or SMA
GE Power ConversionMV6606-4949506.675AFEVSI5 LevelIGBTIGBTIM or SMA
GE Power ConversionMV6606-5555006.67536 PulseVSI5 LevelDiodeIGBTIM or SMA
GE Power ConversionMV6606-5555006.675AFEVSI5 LevelIGBTIGBTIM or SMA
Nidec ASISilcovert TN110018,800 330014012p, 24p, AFEVSI6Diode/IGBTIGBTIMA, W
Nidec ASISilcovert GN780020,900 330010012p, 24p, AFEVSI6Diode/IGBTIGBTIM, SMW
Nidec ASISilcovert TH40021,200 720030018p, 24p, 30p, 36pVSI6DiodeIGBTIM, SMA, W
Nidec ASISilcovert NH130023,800 660014036pVSI6DiodeIGBTIM, SMA, W
Nidec ASISilcovert S150045,000 6600956p, 12p, 24p, AFELCI6, 12ThyristorThyristorSMA, W
Voith TurboVariable Speed
Voith TurboPlanetary Gear100050,000Any motor possibleMotor is operated direct onlineN/AMechanicalN/AN/AN/AIM, SMA, W